MANAGING SWITCH
128
RMON History
The RMON History page allows you to configure the display of history entries.
To access this page, click Management > RMON > RMON History.
Figure 4-101. Management > RMON > RMON History
The following table describes the items in the previous figure.
The ensuing table for History Information settings are informational only: Index, Port,
Buckets Requested, Interval, Owner and Delete (click to delete the desired index).
Table 4-99. Management > RMON > RMON History
Item Description
Index Enter the index entry (1 to 65535) to select the number of new history table
entries.
Port Select the specific port switch.
Buckets Requested Enter the specific (1-50) number of samples to store.
Interval Enter value in seconds (1 to 3600) to designate a specific interval time for
the collection of samples.
Owner Enter the name of the owner of the RMON history group.
Apply Click Apply to save the values and update the screen.