REMOTE OPERATION FREQUENCY HOPPING COMMANDS
4-78
[SOURce][:MODulation]:FHOPping:INTernal:OPERation
Description: Sets whether the frequency hopping mode is linear or random.
Parameters: <CPD>
Valid values: LINear | RANDom
*RST sets: LINear
[SOURce][:MODulation]:FHOPping:INTernal:OPERation?
Description: Returns whether the frequency hopping mode is linear or random.
Parameters: None
Response: <CRD>
Returned values: LIN | RAND
[SOURce][:MODulation]:FHOPping:INTernal:RANDom[:PNCode]
Description: Sets the PN code for frequency hopping.
Parameters: <CPD>
Valid values: PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23
*RST sets:
[SOURce][:MODulation]:FHOPping:INTernal:TRANsition:CLEar[:TEND]
Description: Clears the frequency hopping marker transition points from this point up to the end of
the list. If no value is entered, 0 is assumed, which clears all.
Applies only to instruments fitted with RTBB, Option 008.
Parameters: <numeric_value>
Valid values: <NRf>