REMOTE OPERATION SWEEP COMMANDS
4-158
[SOURce]:SWEep:ABORt
Description: Stops the sweep immediately.
Parameters: None
[SOURce]:SWEep:CONTinue
Description: Continues a paused sweep.
Parameters: None
[SOURce]:SWEep:INITiate
Description: Starts a sweep.
Parameters: None
[SOURce]:SWEep:OPERation
Description: Sets whether the sweep mode is single or continuous.
Parameters: <CPD>
Valid values: SINGle | CONTinuous
*RST sets: SING
[SOURce]:SWEep:OPERation?
Description: Returns whether the sweep mode is single or continuous.
Parameters: None
Response: <CRD>
Returned values: SING | CONT
[SOURce]:SWEep:PAUSe
Description: Pauses the sweep.
Parameters: None
[SOURce]:SWEep:RESet
Description: Resets the sweep to its starting value of power or frequency.
Parameters: None