© Agilent Technologies 1989–2002 Agilent 3070 / 79000 Site Preparation 10-102
Chapter 10: Site Preparation – Power Requirements for Older Systems: Series 3 Power Requirements and Connections (Prior to May 2000)
220/380–240/415 V 3-Phase Wye with Neutral
(0E5, 05L, 0E7)
220/380–240/415 V Single-Phase Wye with Neutral
(05B, 05G, 05K)
Figure 10-63 220/380-240/415 3-phase Wye with neutral (0E5, 05L, 0E7), 220/380-240/415 Single-phase Wye with neutral
(05B, 05G, 05K)
L3L2L1 N
N10A10A
G
1
0
T3T2T1
G
Connect Input
Line here
Note: L3 is available only on 3-phase power
L1 L2
G
N
L1
L3
L2
N
G