E18 Door Phone Administrator Guide
113
20.3. OSDP Setting
OSDP (Open Supervised Device Protocol ) is standard for access control
communications designed to achieve two way communication among the
devices over networks.
If you choose OSDP integration mode, you can not only check for OSDP
status but also obtain the authentication from the third party devices for
various applications such as door access etc. Path:Device > RS485 > OSDP
Advance Setting.
Parameter Set-up:
Connect Status: indicate OSDP based communication status.
Send by: select in what way you want to send out the card number
among three options: OSDP”, “Wiegand and None”. if you select
“OSDP” then the card number will be sent out to the third party devices
via RS485. if you select “Wiegand” then the card number will be sent out
via wiegand. If you select “None” then the card number will not be sent
out but retained in the system.
Note:
Dummy card numbers can not be sent if OSDP is not selected in
the RS485 list field.
20.4.Integration via HTTP API
HTTP API is designed to achieve an network-based integration between the
third party device with the Akuvox intercom device. You can configure the