50 Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 3 Kinetix 300 Drive Connector Data and Feature Descriptions
Ethernet Connections
An RJ45 Ethernet connector (port 1) is provided on the Kinetix 300 drive.
Table 15 - Ethernet Communication Specifications
24V DC Back-up Power
The Kinetix 300 drive can use an external power supply to power the logic and
communication circuits. If an independent 24V (@ 1 A) power supply is
connected to the BP connector, the logic and communication circuits remain
active during a mains input power loss.
Table 16 - 24V DC Back-up Power Specifications
Attribute Value
Communications 100BASE-TX, full duplex
Cyclic update period 2 ms, min
Auto MDI/MDIX crossover
detection/correction
Yes
Cabling CAT5E or CAT6, unshielded or shielded, 100 m (328 ft)
Attribute Value
Input voltage 20…26V DC
Current 500 mA
Inrush, max 30 A