Rockwell Automation Publication 2097-UM001D-EN-P - November 2012 81
Connecting the Kinetix 300 Drive System Chapter 4
Shunt Resistor Connections
Follow these guidelines when wiring your 2097-Rx shunt resistor.
• See Shunt Resistors
on page 32 for noise zone considerations.
• See Shunt Resistor Wiring Example
on page 175.
• See the installation instructions provided with your Bulletin 2097 shunt
resistor, publication 2097-IN002
.
Figure 48 - Shunt/DC Bus (BC) Connector
When tightening screws to secure the wires, see the tables beginning on
page 65
for torque values.
To improve system performance, run wires and cables in the wireways as
established in Chapter 2
.
Kinetix 300 Drive
Front view is shown.
Shunt /DC Bus
(BC) Connector