70 Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 4 Connecting the Kinetix 300 Drive System
Wire the Input Power (IPD) Connector
Table 27 - Input Power (IPD) Connector
L3
L2
L1
PE
L3
L2
L1
L2/N
L1
N
PE
L2/N
L1
N
L2
L1
PE
L2
L1
Kinetix 300 Drive
Top View
Drive Cat. No. Terminals
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2097-V31PR0
2097-V32PR0
2097-V32PR2
2097-V33PR1
2097-V33PR3
2097-V34PR3
2097-V34PR5
2097-V34PR6
L3
L2
L1
PE
(1)
L2/N
L1
N
PE
(2)
L2
L1
PE
(3)
2.5 (14) 7 (0.28) 0.5 (4.5)
2097-V32PR4
2097-V33PR5
4.0 (12) 7 (0.28) 0.5 (4.5)
2097-V31PR2
2097-V33PR6
6.0 (10) 7 (0.28)
0.56…0.79
(5.0…7.0)
(1) Applies to 2097-V33PRx, and 2097-V34PRx drive modules.
(2) Applies to 2097-V31PRx drive modules.
(3) Applies to 2097-V32PRx drive modules.