Programming and Parameters 3-55
Advance Display Group (continued)
d313 [Fault 2 Time-min] Related Parameter(s): A195, d317
Displays the value of the d317 [Elapsed Time-min] parameter when the fault occurred.
Values Default: Read Only
Min/Max: 0.0/60.0 Min
Display: 0.1 Min
d314 [Fault 3 Time-hr] Related Parameter(s): A195, d316
Displays the value of the d316 [Elapsed Time-hr] parameter when the fault occurred.
Values Default: Read Only
Min/Max: 0/9999 Hr
Display: 1 Hr
d315 [Fault 3 Time-min] Related Parameter(s): A195, d317
Displays the value of the d317 [Elapsed Time-min] parameter when the fault occurred.
Values Default: Read Only
Min/Max: 0.0/60.0 Min
Display: 0.1 Min
d316 [Elapsed Time-hr] Related Parameter(s): A195, d310, d312, d314
Displays the total elapsed powered-up time (in hours) since timer reset. The timer stops when it
reaches maximum.
Values Default: Read Only
Min/Max: 0/32767 Hr
Display: 1 Hr
d317 [Elapsed Time-min] Related Parameter(s): A195, d311, d313, d315
Displays the total elapsed powered-up time (in minutes) since timer reset. The timer will increment the
hour parameter when appropriate.
Values Default: Read Only
Min/Max: 0.0/60.0 Min
Display: 0.1 Min
d318 [Output Powr Fctr] Related Parameter(s): T055, T056, T060, T061, T065, T066
The angle in electrical degrees between motor voltage and motor current.
Values Default: Read Only
Min/Max: 0.0/180.0 deg
Display: 0.1 deg