296 Rockwell Automation Publication 1783-UM007G-EN-P - February 2017
Chapter 7 Configure Switch Features
You can add, edit, and delete NTP associations in the table area on the NTP
page. You can add multiple NTP servers.
To add an association, follow these steps.
1. Click Add.
2. In the IP Address field, specify one of the following:
For a peer association, type the IP address of the peer providing, or
being provided, the clock synchronization.
For a server association, type the IP address of the time server
providing the clock synchronization.
3. To make the peer or server the preferred one that provides
synchronization, check the Prefer checkbox.
4. Click OK.
Table 75 - NTP Fields
Field Description
Clock Status Displays the current status of NTP clock synchronization:
Synchronized
Unsynchronized
Stratum Displays the NTP stratum of this system.
The stratum indicates how many NTP hops away a device is from an authoritative time
source.
Reference Displays the address of the peer that the system is synchronized with.
NTP Up Time Displays the uptime of the NTP entity.
Resolution Displays the time resolution of the underlying operating system in milliseconds.
Reference Time Displays the reference time stamp.
Clock Offset Displays the offset of the system clock to the synchronized peer in milliseconds.
Root Delay Displays the total delay along the path to the root clock in milliseconds.
Root Dispersion Displays the number that indicates the maximum error relative to the primary reference
source at the root of the synchronization subnet in milliseconds.
Peer Dispersion Displays the number that indicates the maximum error relative to the synchronized peer
(in milliseconds).
System Poll Interval Displays the poll interval of the peer.
Last Update Displays the time the system last updated its NTP information.

Table of Contents

Other manuals for Allen-Bradley Stratix 5700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Stratix 5700 and is the answer not in the manual?

Allen-Bradley Stratix 5700 Specifications

General IconGeneral
ModelStratix 5700
Port TypesRJ45, SFP
MountingDIN Rail or Panel Mount
DimensionsVaries by model
WeightVaries by model
ManagementWeb-based, SNMP, Command Line
RedundancyDevice Level Ring, STP, RSTP
Operating Temperature-40°C to 70°C
Power SupplyDual DC inputs
Input Voltage24 VDC or 100-240 VAC
ProtocolsEtherNet/IP, DLR
Security FeaturesSSH, HTTPS, RADIUS, TACACS+

Related product manuals