Contents
M370430-01 Rev B ix
Defining the Interlock Mode .................................................................................. 3-36
OUTPUT PROTECTION ..................................................................................... 3-36
Programming Voltage Output Preset .................................................................... 3-36
Programming Current Output Preset .................................................................... 3-37
Power On Status Signal ........................................................................................ 3-38
HARDWARE MALFUNCTION ALARMS ................................................................. 3-38
CURRENT CONFIGURATION MEMORY SETTINGS ................................................ 3-39
USER SETTING MEMORY LOCATIONS ............................................................... 3-40
Saving User Setting Memory Locations ............................................................... 3-40
Recalling User Setting Memory Locations ............................................................ 3-41
LOCAL LOCKOUT ............................................................................................. 3-42
Enabling Local Lockout ......................................................................................... 3-42
Disabling Local Lockout ........................................................................................ 3-42
RESETTING THE POWER SUPPLY...................................................................... 3-43
USING MULTIPLE POWER SUPPLIES ................................................................. 3-45
Configuring Multiple Supplies for Series Operation .............................................. 3-47
Configuring Multiple Supplies for Current Sharing Operation (APG Method) ...... 3-50
Connecting to the Load in Local Sensing Mode (Parallel Control Method) .......... 3-52
Connecting to the Load in Remote Sensing Mode (Parallel Control Method) ...... 3-53
4 ANALOG PROGRAMMING (APG) AND ISOLATED ANALOG
PROGRAMMING (ISOL) ................................................................................. 4-1
INTRODUCTION ................................................................................................. 4-2
Analog Programming (APG) of Output Voltage and Output Current ...................... 4-2
Remote Programming Options ............................................................................... 4-3
Analog Programming (APG) Connector J1 ............................................................ 4-5
ANALOG PROGRAMMING MODE .......................................................................... 4-9
Analog Programming With External Voltage Source .............................................. 4-9
Voltage-Controlled Voltage APG Setup ................................................................ 4-10
Voltage-Controlled Current APG Setup ................................................................ 4-12
Resistive-Controlled Voltage APG Setup ............................................................. 4-15
Resistive-Controlled Current APG Setup ............................................................. 4-17
Voltage and Current Readback ............................................................................ 4-19
ISOLATED ANALOG PROGRAMMING MODE (ISOL) ............................................. 4-20
AUX Output and Isolated Analog Programming (ISOL) Connector ...................... 4-20
Voltage-Controlled Voltage ISOL Setup ............................................................... 4-23
Voltage-Controlled Current ISOL Setup ............................................................... 4-25
Resistive-Controlled Voltage ISOL Setup ............................................................. 4-28
Resistive-Controlled Current ISOL Setup ............................................................. 4-30
VOLTAGE AND CURRENT READBACK (ISOLATED) ............................................... 4-32