Remote Operation
5-42 M370430-01 Rev B
Current SHare Sub-Register
This register shows the state of the current share configuration, which
can either be set through the front panel Current Share Config menu, or
through the SCPI command.
Important: If current sharing is not being used, the unit must be
configured as a controller. Failure to do so will result in unpredictable
operation.
The SCPI command (s) for these instructions are:
[[:]SOURce]:COMBine:CSHare[:MODE]
Table 5-14 OPERation CSHare Status Register
Bit
Bit Weight
Bit Name
Description
0
1
CONTroller
The power supply is configured to be a Current Share
CONTroller.
1
2
SLAVe
The power supply is configured to be a Current Share
Slave.