Ametek Sorensen XG - AC Line Input Specifications for XG;XTR 1500 Watt

Ametek Sorensen XG
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
M370430-01 Rev B
C-5
C
Table C-2 XG/XTR 1500 Watt Electrical Specifications for 6 V to 600 V Models
Models
6-220
8-187.5
12.5-120
20-76
30-50
40-38
60-25
80-19
100-15
150-10
300-5
600-2.6
Efficiency
11
75/77%
77/80%
79.5/
82.5%
82/85%
83/86%
83/87%
83/87%
83/87%
83/87%
83/87%
83/87%
83/87%
1. Maximum output voltage is guaranteed to be ≤ 0.1% of the rated voltage at zero output setting, using the front panel or digital remote programming modes.
2. Maximum output current is guaranteed to be ≤ 0.2% of the rated current at zero output setting, using the front panel or digital remote programming modes, and when measured with rated
load resistance.
3. Total output power doesn’t include AUX1 Output Voltage (5 V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).
4. From 90132 Vac or 170265 Vac, constant load.
5. From 90132 Vac or 170265 Vac, constant load.
6. From no load to full load, constant input voltage.
7. For load voltage change, equal to the unit voltage rating, constant input voltage.
8. For 6 V models the current ripple is measured at 26 V output voltage and full output current. For all other models, the current ripple is measured at 10100% output voltage and full output
current.
9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-220 in an application with
1 V of load line loss (0.5 V/Line), the maximum available load voltage would be 61= 5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee that the
power supply will meet performance specifications. Ultimately, the upper limit of the output voltage will be determined by internal circuitry of the power supply (non-adjustable.)
10. With rated, resistive load.
11. At 100/200 Vac input voltage and maximum output power.
Applies to all footnotes: Programming and Readback: RS-232, RS-485, USB built in. GPIB, Ethernet optional.
Specifications are guaranteed from 1% to 100% of the rated output voltage, current, and power.
AC Line Input Specifications for XG/XTR 1500 Watt
The input to the power supply requires the following input specifications.
Rated AC Input Voltage/Frequency
100240 Vac, 4763 Hz
Operational AC Input Voltage/Frequency
85265 Vac continuous, single phase, 360-440 Hz*, 4763 Hz, single phase
Input Current (at 100/200 Vac)
23/12 A
Inrush Current (100/200 Vac)
Less than 50 A
Power Factor Correction
0.99@100/200 Vac, rated output power
* Contact factory for details regarding this mode of operation.