Remote Operation
M370430-01 Rev B 5-47
5
QUEStionable Status Register
The Questionable Status register is a standard SCPI, 16-bit register
that stores information about questionable events or status during
power supply operation. That is, bits in these registers may indicate
that the output of the supply is of undesirable or questionable
quality.
The Questionable Status data structure consists of a questionable
status register and two sub-registers representing the status of the
voltage outputs and temperature.
Figure 5-23 gives an overview of the Questionable Status data
structure. The “+” represents the logical summation of bits in a
register. Table 5-15, Table 5-16, and Table 5-17 describe the
meanings of each bit as well as the bit number and bit weight.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen XG and is the answer not in the manual?

Ametek Sorensen XG Specifications

General IconGeneral
Output TypeDC
CoolingForced air
Control InterfaceAnalog
Ripple Voltage10 mVrms / 50 mVpp typical
Operating Temperature0°C to +50°C
ProtectionsOVP, OCP, OTP
Output Voltage Range0-5V to 0-600V (depending on model)
Input Frequency47-63 Hz