Local Operation 
 
3-40  M370430-01  Rev B 
User Setting Memory Locations 
There are three user setting memory locations available for storing 
frequently used configurations. These user setting memory locations 
help to facilitate multiple users of an XG/XTR power supply who have 
different setups or when multiple loads are used that have different 
requirements. Table 3-8 lists the values that are stored in each user 
setting memory location. 
Table 3-8  User Accessible Saved/Recalled Settings Voltage Setpoint 
Voltage Output Protection 
Current Output Protection 
Over Voltage Protection (OVP) 
Over Temperature Protection (OTP) 
Autostart OUTPUT ENABLE Main 
Autostart OUTPUT ENABLE Aux 
Voltage Analog Programming (VAP) Mode 
Voltage Analog Programming (VAP) Level 
Current Analog Programming (CAP) Mode 
Current Analog Programming (CAP) Level 
 
Saving User Setting Memory Locations 
To save user setting memory locations: 
1.  Turn the 9-position mode control to the SAV position. 
 is displayed on the output voltage display with a number 
indicating a preset position which is displayed on the output current 
display. 
2.  Turn the rotary Adjust/Enter control to select a preset position 
from 1 to 3. 
3.  Press the rotary Adjust/Enter control. 
 done is displayed on the output voltage display. 
4.  The setting has now been saved to the selected user setting 