EasyManua.ls Logo

Ametek Sorensen XG - User Setting Memory Locations; Saving User Setting Memory Locations; Table 3-8 User Accessible

Ametek Sorensen XG
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Local Operation
3-40 M370430-01 Rev B
User Setting Memory Locations
There are three user setting memory locations available for storing
frequently used configurations. These user setting memory locations
help to facilitate multiple users of an XG/XTR power supply who have
different setups or when multiple loads are used that have different
requirements. Table 3-8 lists the values that are stored in each user
setting memory location.
Table 3-8 User Accessible Saved/Recalled Settings Voltage Setpoint
Voltage Setpoint
Current Setpoint
Voltage Output Protection
Current Output Protection
Over Voltage Protection (OVP)
Over Temperature Protection (OTP)
Autostart OUTPUT ENABLE Main
Autostart OUTPUT ENABLE Aux
Foldback Mode
Foldback Delay
Shutdown Logic
Voltage Analog Programming (VAP) Mode
Voltage Analog Programming (VAP) Level
Current Analog Programming (CAP) Mode
Current Analog Programming (CAP) Level
Current Sharing Mode
Alarm Latches
Front Panel Timeout
Saving User Setting Memory Locations
To save user setting memory locations:
1. Turn the 9-position mode control to the SAV position.
is displayed on the output voltage display with a number
indicating a preset position which is displayed on the output current
display.
2. Turn the rotary Adjust/Enter control to select a preset position
from 1 to 3.
3. Press the rotary Adjust/Enter control.
done is displayed on the output voltage display.
4. The setting has now been saved to the selected user setting
memory location.

Table of Contents