Analog Programming (APG) and Isolated Analog Programming (ISOL)
M370430-01 Rev B 4-31
4
Query for ISOL Current Input Level
To query for ISOL current input level from non-isolated input:
1. Turn the 9-position mode control to the CAP position or press
the rotary Adjust/Enter control if the control knob is already
at the CAP position.
is displayed on the output voltage display.
2. If the mode is currently then select any other ISOL
mode. If this step is done, be sure to restore the ISOL setting
to when the operation is complete. Otherwise, do not
rotate the rotary Adjust/Enter control to keep the current
ISOL mode.
3. Press the rotary Adjust/Enter control to select the ISOL mode.
The output voltage display should read and the output
current display will display ISOL level.
4. Press the rotary Adjust/Enter control to return to normal
mode.
5. If the ISOL mode was modified in step 2, execute the
procedure to deactivate the ISOL voltage mode.
Quick Tip Remote
operation uses these
SCPI commands. See
page 5-1.
The SCPI command for these instructions are:
[:]SYSTem[<channel>]:REMote:SOURce:CURRent <?|LOCal
|AVOLtage|IAVoltage|ARESistive|IAResistive>
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel:CURRent
[:ISOlated]
[:]MEASure[<channel>][:SCALar]:APRogram:CURRent
:ISOlated[:DC]?