Remote Operation
M370430-01 Rev B 5-73
5
Commands:
[:]SYSTem[<channel>]:REMote:SOURce[:VOLTage]
{?|LOCal|AVOLtage|ARESistive}
[:]SYSTem[<channel>]:REMote:SOURce:CURRent
{?|LOCal|AVOLtage|ARESistive}
Where:
LOCal indicates the value is controlled by the set point.
AVOLtage is used to set the output to be controlled by an analog
voltage input.
ARESistive is used to set the output to be controlled by a resistor
circuit.
IAVoltage is used to set the output to be controlled by the isolated
analog voltage input.
IAResistive is used to set the output to be controlled by the isolated
analog resistor circuit.