EasyManua.ls Logo

Ametek Sorensen XG - Environmental Specifications (Indoor use); Mechanical Specifications; Regulatory Approvals

Ametek Sorensen XG
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
C-10
M370430-01 Rev B
Environmental Specifications (Indoor use)
Operating Temperature Range
0 °C to 50 °C, 100% load
Storage Temperature Range
20 °C to 70 °C
Operating Humidity Range
3090% RH (no condensation)
Storage Humidity Range
1095% RH (no condensation)
Operating Altitude
Up to 6,500 feet (2,000 m)
Installation Category
II (IEC 1010-1)
Pollution Degree
2 (IEC 1010-1)
Mechanical Specifications
XG/XTR 850 Watt (W×H×D)
XG/XTR 1500 Watt and 1700 Watt (WxHxD)
8.4 × 1.7 × 19.0 inch (214 × 43.6 × 483 mm)
16.8 × 1.7 × 19.0 inch (428 × 43.6 × 483 mm)
We i g ht
XG/XTR 850 Watt
XG/XTR 1500 Watt and 1700 Watt
11 lb (5kg)
20 lb (9.5 kg)
Cooling
Forced air cooling by internal fans
Regulatory Approvals
Safety
CSA 22.2 No. 61010-1 and UL61010-1. Marked with cCSAus, CE EN61010-1
EMC
Complies with EN61326-1
Complies with EN55022, Class A, FCC Part 15A for conducted emissions
Complies with EN55022, Class A, FCC Part 15A for radiated emissions
Complies with EN61000-4 series of standards for immunity