98 ARR1575
1
7
6
5
4
3
2
557019
555014
6 Cab and platform
6.1.3 Infrared light emitter
6.1.3.1 Layout
1 Working speed (tortoise) / transport speed (hare)
2 Forward / reverse
3 High / low amplitude vibration
4 Steering angle left / right
5 Start / Stop
6 LED indicators
7 Warning horn switch
6.1.3.2 Indication of faults by LEDs on the
infrared light emitter
There are two LEDs on the cover: green and red.
Standard indicator lamp (green)
Indicator lamp Reason
The green LED is ashing slowly The machine is controlled by the infrared remote control and cable
The green LED is ashing rapidly The machine is controlled by the infrared remote control
Battery charge status indicator (red).
The red LED indicator ashes faster or slower depending on the battery charge status.
The more the battery is discharged, the slower the red LED indicator ashes.
When the battery is discharged, the red LED indicator lights continuously.
Controlling via the infrared remote control
Indicator lamp Reason Solution
The red LED is ashing. The battery is running low. Connect the charging cable for at least an hour.
The red LED is on. The battery is discharged, the control does not work. Connect the charging cable for at least an hour.
Controlling via the infrared remote control and cable
Indicator lamp Reason Solution
The red LED is ashing rapidly. The battery is charging.
The red LED is on. The battery is fully charged.