EasyManua.ls Logo

Ammann ARR 1575 - Checking the Travel Pressures (Reverse;Forward)

Ammann ARR 1575
346 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
305ARR1575
1
557D034
557D035A
1
557D036
1
WORKSHOP MANUAL
18.2.5.2 Checking the travel pressures (reverse/
forward)
Pull out the Y9 connector (1) on the valve block.
Connect apressure gauge (at least 400 bar) to the travel pres-
sure measuring point (1).
Start the engine.
Full speed
Reverse while braking.
Let it run for no more than 5 seconds.
Connect a pressure gauge (at least 400 bar) to the MB travel
pressure measuring point (1).
Start the engine.
Full speed
Drive forward while braking.
Let it run for no more than 5 seconds.
If atravel pressure of 330 ± 15 bar is not reached:
check the travel hydraulic motors (Chapter 18.2.6).
check the maximum pressure of the travel pump.
If it is still not reached, replace the travel pump. See “Replace-
ment of the travel pump (Chapter 11.2.1).