257ARR1575
557D124
557D125
557D126
557D127
WORKSHOP MANUAL
15.3.3.1 Battery replacement
Loosen the (–) clamp and remove it.
Loosen the (+) clamp and remove it.
Loosen the holding angle piece and remove it.
Lift the battery from the machine area.
Insert anew battery.
Connect the battery.
Start with the (+) clamp.
Battery poles and clamps must be clean. If they show
a coat of sulphate (whitish or greenish), they must be
cleaned.