287ARR1575
WORKSHOP MANUAL
18.1.2 Start of the conductor and infrared radiation test
Normal test
Open the cab cover.
Open the cover without covering the sensor.
Turn the ignition on.
Keep adistance of three metres from the roller.
Always keep an eye on the safety bar indicator lamp.
If the safety bar indicator lamp is ashing, increase the distance from the roller.
Hold down the switch button on the infrared sensor.
The preheating indicator lamp must be on.
If the preheating indicator lamp is o, reduce the distance from the roller.
When the preheating indicator lamp turns on, the roller starts after 6 seconds.
Quick start
Open the cab cover.
Open the cover without covering the sensor.
Turn the ignition on.
Keep adistance of three metres from the roller.
Always keep an eye on the safety bar indicator lamp.
If the safety bar indicator lamp is ashing, increase the distance from the roller.
Hold down the switch button on the infrared sensor.
The preheating indicator lamp must be on.
If the preheating indicator lamp is o, reduce the distance from the roller.
When the preheating indicator lamp turns on, immediately let go of the switch. Start the engine.