290 ARR1575
18 Troubleshooting
18.1.4 Control does not work
To localize and remove the fault, proceed step by step as described below.
18.1.5.1 External inuences
Reective surfaces (mirrors, reective stripes...) in the vicinity may interfere with the remote control distance detection.
Under certain circumstances, special light sources (uorescent lamps, light beacons...) may interfere with infrared communication.
The control may be adversely aected by strong electromagnetic radiation (e.g. near high-current equipment).
If the faults occur only in certain locations or situations, check the area for the above interference and try to avoid it.
18.1.5.2 Machine cabling
Are fuses F11 and F12 OK?
Are the connectors on the N1 control unit dirty or wet?
Is the N1 control unit properly fastened?
Are both infrared sensors P1 and P2 clean and undamaged?
Is the cabling from N1 to P1 and P2 undamaged? Do not forget that there is the X5 interconnecting connector near the sensor at
the front of the engine compartment.
Are the N3 manual control cable and the corresponding connectors undamaged and clean? Do not forget the X1 connector on the
inside of the bonnet.