To reset the EDID of an input:
Front Panel
1. Enter the CUSTOMIZE menu in the Front Panel interface.
2. Scroll down and select EDID Manager to access the EDID management menu.
3. Select INPUTS to access the VIO 4K input EDIDs.
4. Select an input and press the ENTER key to edit the EDID of the selected input.
5. Select Reset to default EDID to reset to default values the EDID of the selected input.
TIP: Use the INPUTS > Reset all inputs EDID to default EDID command to reset all inputs EDIDs at once.
Web RCS
1. Go to the Setup menu on the Web RCS interface.
2. Click on the CONTROL tab to access the device settings and control functions.
3. In the left side toolbar, select EDID to access the EDID management page.
4. In the Inputs window, click on the Set EDIDs to default values button to reset all input EDIDs to
default values.