Alternative method:
1. Enter the OUTPUTS menu on the Front Panel interface.
2. Select STANDARD OUTPUT to access the standard output setup menu.
3. Scroll down the output setup menu and select Monitor on LCD to enable output monitoring on
the front panel LCD screen (press the EXIT-MENU button to exit monitoring).
Web RCS
1. Go to the Edit menu on the Web RCS interface.
2. Select the MON. STREAM tab to access the monitoring page.
3. Go to the Properties toolbar on right-hand side.
4. Under Setup > Source, scroll down and select STANDARD OUTPUT.
5. If required, select the Quality of the monitoring stream.
TIP: Use the Play and Fullscreen buttons at the bottom of the monitoring screen to control the monitoring
stream playback and display size.
NOTE: You can also disable the Audio > Mute button to monitor the headphone output directly from your PC or tablet (SEE:
Prelistening to audio content for more information).
You can freeze the live content of your output to make some adjustments on the currently selected input
while hiding them to the spectator, for example.