1010..22 No Frame TestNo Frame Test
No Frame Test is the test which uses the pattern without frame structure. No Frame
Test measures the BER (bit error rate) and the frequency.
1010..22..11 Ports Setup and StatusPorts Setup and Status
The first step in running an application is to set up the port interfaces. This is
done on the Ports SetupPorts Setup screen, which also provides port status information.
The setup options and status information related to the Ethernet interface are
described in a separate section:
Device Test Setup and Status
1010..22..22 Test SetupTest Setup
1010..22..22..11 ControlControl
When you go to the test setup of the No Frame application, the following
screen is displayed.
This screen contains the parameters that are generally required in a No Frame
test setup.
Interval lengthInterval length
Allows you to specify the duration of the intervals. The drop-down menu
contains the following values: 11, 22, 55, 1010, 1515, 30 seconds30 seconds, 11, 55, 1010, 1515, 30 min.30 min.,
11, 22, 44, 66, 12 hours12 hours or No IntervalsNo Intervals.
Start actionStart action
Allows you to specify when the measurement is started.
If ImmediateImmediate is selected, the measurement starts when you touch the StartStart
button.
Selecting Start atStart at will enable a delayed start. The start time for a delayed start
can be specified in the adjacent Start atStart at field.