Chapter 7 Remote Commands
7-32
Table 7.3.2.1-1 Result Setting Commands
No. Item Command
[1]
Start :DEMux:MEASure:STARt
[2]
Stop :DEMux:MEASure:STOP
[3]
Query measurement conditions :DEMux:MEASure:EALarm:STATe?
[4]
Zoom :DEMux:RESult:ZOOM
:DEMux:RESult:ZOOM?
[5]
History Reset :DEMux:RESult:EALarm:HRESet
[6]
No label
(Query measurement data of error alarm)
:DEMux:CALCulate:DATA:EALarm?
[7]
No label
(Query window items)
:DEMux:CALCulate:DATA:MONitor?
:DEMux:MEASure:STARt
Function Starts MP1862A BER measurement in same unit and restarts during
measurement.
Example To start MP1862A BER measurement in same unit:
> :DEMux:MEASure:STARt
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:MEASure:STOP
Function Stops MP1862A BER measurement in same unit.
Example To stop MP1862A BER measurement in same unit:
> :DEMux:MEASure:STOP
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:MEASure:EALarm:STATe?
Response <numeric>=< NR1 NUMERIC RESPONSE DATA >
0 Stopped
1 Measuring
Function Queries measurement progress at MP1862A bit error or alarm in same unit.
Example > :DUMux:MEASure:EALarm:STATe?
< 0
Compatibility Compatible with MU182040A and MU182041A.