28
Line, Sub-line Parameter Setting,
basic
Setting,
range
Authorization
96 08 Activation rinse-aid
low level
0 Input: 0 = not
active, 1 = active
C
96 09 Activation rinse-aid empty 0 Input: 0 = not
active, 1 = active
C
96 10 Activation, process agent,
low level
0 Input: 0 = not
active, 1 = active
C
96 11 Activation, process agent,
empty
0 Input: 0 = not
active, 1 = active
C
96 12 Activation spray agent
low level
0 Input: 0 = not
active, 1 = active
C
96 13 Activation spray agent
empty
0 Input: 0 = not
active, 1 = active
C
96 14 Activation, leakage
sensor 1
1 Input: 0 = not
active, 1 = active
C
96 15 Activation, door closed 1 1 Input: 0 = not
active, 1 = active
C
96 16 Activation, door locked 1 1 Input: 0 = not
active, 1 = active
C
96 17 Door open (FD1810) 1 Input: 0 = not
active, 1 = active
C
96 20 Safety switch door closing
(FD1810)
1 Input: 0 = not
active, 1 = active
C
96 21 Pedal (FD1810) 0 Input: 0 = not
active, 1 = active
C
Line 97: Activation, outputs
97 01 Activation, pressure pump 1 Input: 0 = not
active, 1 = active
C
97 01 Activation, steam generator 1 Input: 0 = not
active, 1 = active
C
97 03 Activation, cold water 1 Input: 0 = not
active, 1 = active
C
97 04 Activation, hot water 1 Input: 0 = not
active, 1 = active
C
97 05 Activation, soft water 0 Input: 0 = not
active, 1 = active
C
97 06 Activation PE system
(rotary nozzle)
0 Input: 0 = not
active, 1 = active
C
97 07 Activation SP system
(spray nozzle)
For future use
97 08 Activation Extra nozzle For future use
97 09 External rim washing For future use
97 10 Activation, pump, descaling 1 Input: 0 = not
active, 1 = active
C
97 11 Activation pump chemical
agent
0 Input: 0 = not
active, 1 = active
C