260-668080-001 Rev 002 March 2013 5
Eclipse Edge User Manual
Additional Information
A checksum is used to determine configuration status during power-up and software
reloads. It may also be prompted during a reconfiguration.
Fixed Flash Failure
Loss of communications with fixed flash memory. This is a warning alarm.
Probable Cause
Equipment or process malfunction.
Recommended Actions
Reboot (power off, pause, power on). If the alarm remains, replace the IDU.
Additional Information
Fixed flash memory is checked during power-up and software reloads.
Flash Card Failure
Loss of communications with the flash card. This is a warning alarm.
Probable Cause
Flash card or process malfunction.
Recommended Actions
Reboot (power off, pause, power on). If the alarm remains, replace the IDU.
Additional Information
The flash card memory function is checked during power-up and software reloads.
Loss of communications means the configuration for the terminal cannot be
accessed.
Replacing a flashcard requires return of the IDU to a service center.
Date and Time Not Set
Date and time have not been set. This is a warning alarm.
Probable Cause
Configuration incomplete.
Recommended Actions
Use the Portal Date/Time screen to configure the settings.
RAM Failure
The RAM test has failed. This is a warning alarm.
Probable Cause
Equipment or process malfunction.
Recommended Actions
1. Check for other alarms to determine how critical the test failure is. Depending on
the malfunction, the node may otherwise operate satisfactorily.
2. Reboot (power off, pause, power on).