260-668080-001 Rev 002 March 2013 91
Eclipse Edge User Manual
History Screen: Ethernet
The Ethernet History screens support graph, report, and combined graph and report
screen views for the DAC ES module.
15-minute or 24-hour resolution options are provided:
15-minute provides viewing of seven days worth of 15 minute data bins.
24-hour provides one months worth of 1 day data bins.
Both 15-minute and one-day data bins are captured from power-on. The data is held
on a FIFO basis; data in excess of the 15 minute or daily bin maximums is deleted in
favor of new-in data.
Statistical data is lost when the dc supply is turned off, or when a new SW version is
loaded.
The data captured includes:
Ethernet Rx and Tx statistics
•Events
Configuration changes
The Graph Screen, as shown in Figure 4-30, shows a typical opening screen. It
default opens to 15 minute resolution.
3 Left click within the view, and drag to the left or right to set a
report range. The range is shown by blue highlighting.
Once a range is selected, it also displays in the graph screen,
and can be adjusted from within the graph screen by clicking
and dragging edges in the expanded view.
4 Summary data for the selected report range. Data displayed is
RSL (min, max, mean), BER (min, max, mean), errored
seconds, seriously errored seconds, unavailable seconds, and
frame loss seconds.
5 Click Events to view a listing of events for the selected period.
The listing mirrors the listing for the same period in the Events
Browser screen.
Item Description

Table of Contents