30 Aviat Networks
Chapter4. Eclipse Edge Configuration and Diagnostics
5. Configuration: Information
Select Configuration > Information and enter data in the user configurable fields
for terminal and site name, contact details and site grid.
Refer to Terminal Information on page 35 for details.
6. Configuration: System Layout
System Summary displays the layout of the terminal modules. Physical layout is fixed.
7. Configuration: Plug-ins
Select Configuration > Plug-Ins to view settings for the terminal modules.
Edit using the settings specified in the installation datapack. The dual ODU protection
option is set in this screen. Remove the Tx Mute, if set. Refer to Plug-ins on page 35
for details.
8. Configuration: Circuits
The IDUspe 16x includes a Circuits screen. Select Configuration > Circuits to view
and set.
Refer to Circuits on page 53 for details.
9. Configuration: Networking
Select Configuration > Networking to set IP addressing and routing, and if
required, trap destinations.
Refer to Networking Configuration on page 55 for details.
10. Configuration: Date/Time
Select Configuration > Date/Time to set the Terminal date and time.
For details refer to Date and Time Configuration on page 71
11. Configuration: Software Management
Select Configuration > Software Management to check and compare the loaded
software against the version supplied on the Installation CD. Where different, load the
version from the CD, which is the latest version at the time of shipping from Aviat
Networks.
Refer to Software Management on page 73 for details.
12. Configuration: Security
Select Configuration > Security to enable login security for Portal, and to set new
passwords.
Refer to Security Configuration on page 78 for details.
13. Align the antenna using either the RSSI voltage at the BNC connector on the ODU
or the RSL value on Portal.
To view the RSL value select Diagnostics > Performance. Refer to
Performance on page 95.
14. Repeat steps 2 to 16 for the other end of the link.
15.
Record the RSL at both ends of the link and check values against the expected RSLs
in the installation datapack.
16. Complete a BER test. Loopbacks are available within Portal under Diagnostics. For
details, refer to System/Controls on page 104.