EasyManuals Logo

Basler L304kc User Manual

Default Icon
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Camera Interface
BASLER L304
kc 2-7
Draft
2.4 Input Signals
An external sync (ExSync) signal is the only control signal that can be input into an L304kc
camera.
2.4.1 ExSync: Controls Line Readout and Exposure Time
The ExSync input signal can be used to control exposure time and line read out. The ExSync
signal is an RS-644 LVDS signal as specified in the Camera Link standard and is usually supplied
to the camera by the frame grabber. The signal is input to the camera on pins 9 and 22 of the 26-
pin MDR connector as specified in the Camera Link standard.
When the camera is operating with an ExSync signal, three exposure time control modes are
available: edge-controlled, level-controlled and programmable. For more detailed information on
the three modes, see Section 3.3.
The period of the ExSync signal determines the camera’s line rate:
Note that ExSync is edge sensitive and therefore must toggle.
Minimum high time for the ExSync signal is 0.1 µs.
Line Rate
1
ExSync Signal Period
---------------------------------------------------------
=

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler L304kc and is the answer not in the manual?

Basler L304kc Specifications

General IconGeneral
BrandBasler
ModelL304kc
CategorySecurity Camera
LanguageEnglish

Related product manuals