Operation and Features
BASLER L304
kc 3-39
Draft
3.8.1 Enabling and Setting the Stamp
You can enable and set the stamp feature with the Camera Configuration Tool Plus (CCT+) or by
using binary write commands from within your own application to set the camera’s control and
status registers (CSRs).
With the CCT+
With the CCT+ (see Section 4.1), you use the Stamp Mode parameter in the Stamp parameters
group to enable the stamp.
You use the Stamp Red High Pixel Threshold, Stamp Green High Pixel Threshold and Stamp Blue
High Pixel Threshold parameters to set the high pixel thresholds.
You use the Stamp Red Low Pixel Limit, Stamp Green Low Pixel Limit and Stamp Blue Low Pixel
Limit parameters to set the low pixel limits.
By Setting CSRs
You enable the stamp feature by writing a value to the Mode field of the Stamp Mode CSR (see
page 4-27).
You set the red, green, and blue high pixel thresholds by writing values to the High Pixel Threshold
field in the Stamp Red High Pixel Threshold CSR, the Stamp Green High Pixel Threshold CSR
and the Stamp Blue High Pixel Threshold CSR (see pages 4-29 and 4-30).
You set the red, green, and blue low pixel limits by writing values to the Low Pixel Limit field in the
Stamp Red Low Pixel Limit CSR, the Stamp Green Low Pixel Limit CSR and the Stamp Blue Low
Pixel Limit CSR (see pages 4-28 and 4-30).
See Section 4.2.2 for an explanation of CSRs and Section 4.3.1 for an explanation of using read/
write commands.