3.12 CCD Temperature Sensor
L304kc cameras are equipped with a feature that lets you monitor the temperature of the CCD
sensor. You can check the temperature of the CCD sensor with the Camera Configuration Tool
Plus (CCT+) or by using binary read commands from within your own application to read the
camera’s inquiry registers.
With the CCT+
With the CCT+ (see Section 4.1), you use the Sensor Temperature parameter in the Camera
Information parameters group to check the temperature of the CCD sensor.
By Reading Inquiry Registers
You check the temperature of the CCD sensor by reading the Temperature field of the Sensor
Temperature Inquiry Register (see page 4-11).
See Section 4.2.1 for an explanation of Inquiry Registers and Section 4.3.1 for an explanation of
using read/write commands.
L
If the temperature of the CCD sensor rises above 75° C, an overtemperature error
will be declared. See Section 3.13.2 for more information.