EasyManua.ls Logo

Basler L304kc - Resetting the Camera

Default Icon
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation and Features
3-64 BASLER L304kc
Draft
3.16 Resetting the Camera
You can initiate a camera reset with the Camera Configuration Tool Plus (CCT+) or by using binary
write commands from within your own application to set the camera’s control and status registers
(CSRs). A reset is the equivalent of switching off power to the camera and switching power back
on.
With the CCT+
With the CCT+ (see Section 4.1), click on “Camera” in the menu at the top of the CCT+ window
and a drop down list will appear. Click on “Reset Camera” in the drop down list to initiate a reset.
By Setting CSRs
You can initiate a reset by writing a value to the Reset field of the Camera Reset CSR (see page
4-36).
See Section 4.2.2 for an explanation of CSRs and Section 4.3.1 for an explanation of using read/
write commands.
L
Whenever the camera is powered on or when a camera reset is performed, your PC
may receive one random character on the serial interface. We recommend clearing
the serial input buffers in your PC after a camera power on or reset.

Table of Contents

Related product manuals