3.16 Resetting the Camera
You can initiate a camera reset with the Camera Configuration Tool Plus (CCT+) or by using binary
write commands from within your own application to set the camera’s control and status registers
(CSRs). A reset is the equivalent of switching off power to the camera and switching power back
on.
With the CCT+
With the CCT+ (see Section 4.1), click on “Camera” in the menu at the top of the CCT+ window
and a drop down list will appear. Click on “Reset Camera” in the drop down list to initiate a reset.
By Setting CSRs
You can initiate a reset by writing a value to the Reset field of the Camera Reset CSR (see page
4-36).
See Section 4.2.2 for an explanation of CSRs and Section 4.3.1 for an explanation of using read/
write commands.
L
Whenever the camera is powered on or when a camera reset is performed, your PC
may receive one random character on the serial interface. We recommend clearing
the serial input buffers in your PC after a camera power on or reset.