iv
Safe Use Specifications and Compliance
Table 5 lists the safe use specifications for the CFX96 system or the CFX384 System. Shielded cables
(supplied) must be used with this unit to ensure compliance with the Class A FCC limits.
REGULATORY COMPLIANCE
This instrument has been tested, and found to be in compliance with all applicable requirements of the
following safety and electromagnetic standards:
IEC 61010-1:2001 (2nd Ed.), EN61010-1:2001 (2nd Ed). Electrical Equipment For
Measurement, Control, and Laboratory Use - Part 1: General Requirements
IEC 61010-2-010:2005, EN61010-2-010:2003. Safety requirements for electrical equipment
for measurement, control and laboratory use. Part 2-010: Particular requirements for
laboratory equipment for the heating of materials
IEC 61010-2-081:2001+A1, EN61010-2-081:2002+A1. Safety requirements for electrical
equipment for measurement, control and laboratory use. Part 2-081: Particular requirements
for automatic and semi-automatic laboratory equipment for analysis and other purposes
(includes Amendment 1)
EN 61326-1:2006 (Class A) Electrical equipment for measurement, control and laboratory
use. EMC requirements, Part 1: General requirements
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Table 5. Safe Use Specifications
Safe Use Requirements Specifications
Temperature Indoor use
Ambient temperature of 15—31
o
C. Relative humidity
maximum of 80% noncondensing
Altitude Up to 2,000 meters above sea level

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BIO RAD CFX96 and is the answer not in the manual?

BIO RAD CFX96 Specifications

General IconGeneral
Temperature Uniformity±0.4 °C
SoftwareCFX Maestro Software
Detection MethodReal-time PCR (qPCR)
Sample Capacity96-well plate
Excitation SourceLED
Ramp RateUp to 5°C/sec
Heating Rate5°C/sec
SensitivitySingle copy detection
Power Requirements100-240 V, 50/60 Hz
Temperature Range0–100 °C

Related product manuals