BOCA PRO16 Reference Guide
S REGISTER MEANING
2 Escape Sequence Character
S Register 2 contains the ASCII value of the characters which form the
escape sequence.
The default value for this register is 43. The modem will recognize three
+ characters (+++) as the escape sequence.
Setting this register to a value greater than 127 disables the modem’s
recognition of the escape character.
Examples
ATS2=36 Recognize three $ ($$$) characters as the escape sequence
ATS2=64 Recognize three @ (@@@) characters as the escape sequence
Default 43 (the + character)
See Also
S Register 12 (Escape Sequence Guard Time)
Range 1-255
S REGISTER MEANING
3 Carriage Return Character
S Register 3 contains the ASCII value of the character recognized by the
modem as the Carriage Return character in local command state.
Default 13
Example
ATS3-127 Recognize the DEL character as the carriage return
Range 0-127