BOCA PRO16 Reference Guide
S REGISTER MEANING
12 Escape Sequence Guard Time
The Escape Sequence Guard Time is the time delay required immedi-
ately before and after entering an escape sequence.
For your modem to distinguish the escape sequence from ordinary data,
there must be a period of silence both before and after the escape
sequence is entered.
If the Escape Sequence Guard Time is one second and the escape
sequence character has been defined as +, for the modem to recognize an
escape sequence you must maintain silence on the line for one second,
then type +++ in rapid succession, and then maintain another second’s
silence.
The guard time is in units of 20 milliseconds (or 1/50 of a second).
FS Register 12 is also used to time the period between the escape
sequence characters as they are typed. If the period between the first
and second escape characters or second and third escape characters
being entered is greater than the value in S Register 12, the modem will
not recognize the escape sequence.
Examples
ATS12=100 Maintain silence on the line for 2 seconds before and after
entering the escape sequence
Default 50