BOCA PRO16 Reference Guide
S REGISTER MEANING
43 Break Sequence Length
The value in S Register 43 defines the length of a break (long space)
sequence generated by the modem to your computer when constant
speed, reliable or auto-reliable modes are selected.
The \B command determines the length of breaks to the remote modem.
Each unit is equivalent to 0.02 second.
FS Register 43 does not affect the length of the break generated by the
modem when variable speed mode is selected. In variable speed
mode, the Y command controls the length of breaks generated by the
modem.
Examples
ATS43=10 Generate a break of 0.2 seconds
Default 15
See Also
Y command Long Space Disconnect
\B command Generate Break
Range 1-255
S-Registers
S-Registers