BOCA PRO16 Reference Guide
Reliable Mode
Reliable mode allows the modem to use error correction to connect to
another modem. If the modem you attempt to connect to does not
support a compatible method of error correction, your modem will hang
up and return a NO CARRIER message.
Use \N6 to select V.42/MNP reliable mode, \N4 to select V.42-only
reliable mode or \N2 to select MNP-only reliable mode.
Auto-Reliable Mode
Auto-reliable mode allows your modem to use V.42 or MNP if the
remote modem also supports these. If the remote modem does not
support a compatible type of error correction, your modem will fallback
to either constant speed or variable speed mode.
FThe \J command determines whether your modem falls back to
constant speed or variable speed mode.
\N3 selects V.42/MNP auto-reliable mode and \N5 selects V.42-only
auto-reliable mode. Your modem supports special CONNECT mes-
sages for connections made with either reliable or auto-reliable modes.
When the AT\V1 command is issued and your modem connects in
either reliable or auto-reliable mode, one of the following messages will
be sent to your computer.
NUM/VERBAL
20 CONNECT/REL 300bps connection with error correction
22 CONNECT 1200/REL 1200 bps connection with error correction
23 CONNECT 2400/REL 2400 bps connection with error correction
24 CONNECT 4800/REL 4800 bps connection with error correction
25 CONNECT 9600/REL 9600 bps connection with error correction
26 CONNECT 12000/REL 12000 bps connection with error correction
27 CONNECT 14400/REL 14400 bps connection with error correction
28 CONNECT 7200/REL 7200 bps connection with error correction
43 CONNECT 16800/REL 16,800 bps connection with error correction
44 CONNECT 19200/REL 19,200 bps connection with error correction
45 CONNECT 21600/REL 21,600 bps connection with error correction
46 CONNECT 24000/REL 24,000 bps connection with error correction
47 CONNECT 26400/REL 26,400 bps connection with error correction
48 CONNECT 28800/REL 28,800 bps connection with error correction
49 CONNECT 38400/REL 38,400 bps connection with error correction
50 CONNECT 57600/REL 57,600 bps connection with error correction
70 CONNECT 76800/REL 76,800 bps connection with error correction
71 CONNECT 96000/REL 96,000 bps connection with error correction
72 CONNECT 115200/REL 115,200 bps connection with error correction
73 CONNECT 230400/REL 230,400 bps connection with error correction
Error Correction
Error
Correction
pro16ref.pm6 6/14/96, 2:36 PM29