13.4.1 Block Diagram
The following table describes the software switches shown in the circuit diagram as a
function of the selected
Reference Frequency Source 475.
Switch position on circuit diagram
Operation
mode
MFI1A FF MP F1 F3 KP Sign
1 1 Abs. value
10 1 Abs. value
11 1 1 Abs. value
20 1 Abs. value
21 1 1 Abs. value
30 1 Abs. value
31 1 1 Abs. value
32 1 Abs. value
33 1 1 Abs. value
40 1 Abs. value
41 1 1 Abs. value
80 1 1 1 1 Abs. value
81 1 1 1 1 1 Abs. value
82 1 1 1 1 Abs. value
89 1 1 1 1 1 Abs. value
90 1 1 1 1 Abs. value
91 1 1 1 1 1 Abs. value
92 1 1 1 1 Abs. value
99 1 1 1 1 1 Abs. value
101 1 +/-
110 1 +/-
111 1 1 +/-
120 1 +/-
121 1 1 +/-
130 1 +/-
131 1 1 +/-
132 1 +/-
133 1 1 +/-
140 1 +/-
141 1 1 +/-
180 1 1 1 1 +/-
181 1 1 1 1 1 +/-
182 1 1 1 1 +/-
189 1 1 1 1 1 +/-
190 1 1 1 1 +/-
191 1 1 1 1 1 +/-
192 1 1 1 1 +/-
199 1 1 1 1 1 +/-