Operating Instructions ACTIVE 06/0718
18 Operating Instructions ACTIVE 06/07
3.3 ACT 201 (0.55 up to 3.0 kW, 230 V)
Type
ACT 201
-05 -07 -09 -11 -13 -15
Output motor side
Recommended shaft output
P kW 0.55 0.75 1.1 1.5 2.2 3.0
4)
Output current
I A 3.0 4.0 5.4
5)
7.0 9.5 12.5
4) 5)
Long-term overload current (60 s)
I A 4.5 6.0 7.3 10.5 14.3 16.2
Short-term overload current (1 s)
I A 6.0 8.0 8.0 14.0 19.0 19.0
Output voltage
U V Maximum up to mains voltage, three-phase
Protection
- - Short circuit / earth fault proof
Rotary field frequency
f Hz 0 ... 1000, depending on switching frequency
Switching frequency
f kHz 2. 4. 8. 12. 16
Output brake resistor
min. brake resistor
R 100 100 100 37 37 37
Recommended brake resistor
(U
dBC
= 385 V)
R 230 160 115 75 55 37
Input, mains side
Mains current
3)
, 3ph/PE
1ph/N/PE; 2ph/PE
I A
3
5.4
4
7.2
5.5
1)
9.5
2)
7
13.2
9.5
16.5
2)
10.5
1)
16.5
2) 4) 7)
Mains voltage
U V 184 ... 264
Mains frequency
f Hz 45 ... 66
Fuse 3ph/PE
1ph/N/PE; 2ph/PE
I A
6
10
10
16
16
20
16
20
UL Type 250 VAC RK5, 3ph/PE
1ph/N/PE; 2ph/PE
I A
6
10
10
15
15
20
15
20
Mechanics
Dimensions
HxWxD
mm 190x60x175 250x60x175
Weight (approx.)
m kg 1.2 1.6
Degree of protection
- - IP20 (EN60529)
Terminals
A mm
2
0.2 ... 1.5
Form of assembly
- - vertical
Ambient conditions
Energy dissipation
(2 kHz switching frequency)
P W 43 53 73 84 115 170
Coolant temperature
T
n
°C 0 ... 40 (3K3 DIN IEC 721-3-3)
Storage temperature
T
L
°C -25 ... 55
Transport temperature
T
T
°C -25 ... 70
Rel. air humidity
- % 15 ... 85; not condensing
If required by the customer, the switching frequency may be increased if the output current is reduced at the
same time. Comply with the applicable standards and regulations for this operating point.
Output current
6)
Switching frequency
Frequency inverter nominal power
2 kHz 4 kHz 8 kHz 12 kHz 16 kHz
0.55 kW 3.0 A 3.0 A 3.0 A 2.5 A 2.0 A
0.75 kW 4.0 A 4.0 A 4.0 A 3.4 A 2.7 A
1.1 kW 5.4 A
2)
5.4 A
2) 5)
5.4 A
2) 5)
4.5 A
2) 5)
3.7 A
5)
1.5 kW 7.0 A 7.0 A 7.0 A 5.9 A 4.8 A
2.2 kW 9.5 A
2)
9.5 A
2)
9.5 A
2)
8.0 A
2)
6.5 A
3.0 kW
2) 4)
12.5 A
1)
12.5 A
1) 5)
12.5 A
1) 5)
10.5 A
1) 5)
8.5 A
5)
1)
Three-phase connection requires a commutating choke.
2)
One- and two-phase connection requires a commutating choke.
3)
Mains current with relative mains impedance 1% (see chapter„Electrical installation“)
4)
Maximum output current is 9.5 A for one- and two-phase connection.
5)
Switching frequency is reduced in thermal limit range
6)
Maximum current in continuous operation
7)
The device for one-phase connection is not included in the product catalogue. It is available on demand.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Act 201 and is the answer not in the manual?

BONFIGLIOLI Act 201 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelAct 201
CategoryDC Drives
LanguageEnglish

Related product manuals