Operating Instructions ACTIVE 06/0716
16 Operating Instructions ACTIVE 06/07
3 Technical Data
3.1 General technical data
CE conformity The frequency inverters ACT meet the requirements of the low-volta
e directive
73/23/EEC and the requirements of the standards EN 50178 and EN 61800-2.
EMC directive For proper installation of the frequency inverter in accordance with the standard
EN 61800-3 comply with the installation instructions in this operation manual.
Interference
immunity factor
The frequency inverters meet the requirements of the standard EN 61800-3 fo
r
operation in industrial environment.
UL approval
The frequency inverters are marked with the UL label according to UL508c, which
proves that they also meet the requirements of the CSA Standard C22.2-No. 14-
95.
Ambient
temperature
Operation: 0 … 55 °C; for exceeding 40 °C comply with the derating.
Climate class Operation: 3K3 (EN60721-3-3)
Relative air humidity 15 ... 85 %, not condensing
Degree
of protection
IP20 on the condition of proper installation of the covers and terminals.
Mounting altitude Up to 1000 m at rated operating conditions.
Up to 4000 m with derating.
Storage According to EN 50178;
BONFIGLIOLI VECTRON recommends the connection of the device to mains volt-
age for 60 minutes latest after one year of storage.
Functions Appropriate control behaviours (configurations) adapted for motors and applica-
tions
− Speed-/torque control switch-over
− Various protective functions for motor and frequency inverter
− Positioning absolute or relative to a reference point
− Synchronization to a rotating drive
− Special brake control and load detection for hoist drives
− S-ramps for jerk limitation at acceleration and deceleration
− Technology- (PI) controller
− Parameterization of master-slave operation via system bus
− Error protocol
− Simplified and enhanced operation via PC (commissioning, parameterization,
record back-up, diagnosis with scope)
Parameterization
− Freely programmable digital inputs and outputs
− Various modules for logical operations and signal processing
− Four discrete records including motor parameters