3. FUNCTION SETTINGS
18
Error processing settings (600 to 699)
No. Setting range
Initial
value
Setting
units
Setting details
650
OFF
230
(seconds)
OFF
1
Timing until busser stop when error occur
OFF: No stopping for Buzzer sound
2 to 30: Buzzer sound stops after specifying time
651
1
30
(minutes)
3
(minutes)
1
Continuous running mode for preventing sewing motor will be over heated
1 - 30 : After continuous operatio
n for the set length of time, operation
stops and [E190] is displayed.
Maintenance settings (700 to 799)
No. Setting range
Initial
value
Setting
units
Setting details
750
0
99
0
1
Machine ID code
The destination folder for data storage on USB media is
¥BROTHER¥ISM¥ISMDF**¥
This is not initialized during initialization mode.
Specifications and destination settings (800 to 899)
No. Setting range
Initial
value
Setting
units
Setting details
850
0
2
(*8)
1
Language
0: Chinese
1: English
2: Japanese
This is not initialized during initialization mode.
851
ON/OFF
(*9)
-
PRE foot operation by treadle
ON: Europe specifications
Set by MSW-001, MSW-055
OFF: Other than Europe and America
After T/T, when treadle is retuned to neutral, PRE foot is up.
Presser foot lowering when machine motor stops with the presser
foot in the raised position, and then the presser foot is lowered and
the treadle is then moved to the neutral position
This is not initialized during initialization mode.
852
ON/OFF
(*9)
-
Presser foot down when treadle forward 1st step
ON: depends on MSW-057 setting
OFF: Disabled
This is not initialized during initialization mode.
(*8) For China: 0
For Japan: 2
For other than the above: 1
(*9) For other than Europe and America: OFF