EasyManua.ls Logo

Brother TC-32B - Variable Display and Setting

Brother TC-32B
240 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Macro TC-32B
2004/01/22 7 - 6 eTCOMNCPR7-1.doc
7
7.2.5 Variable display and setting
Variables are displayed and manually set on the data bank screen.
Press the [3] and [ENT] keys at the data bank menu screen, or shift the cursor to the menu No.3
and press the [ENT] key. The following items are displayed on the screen.
Common variables (#100~#199, #500~#999) and local variables can be referred to or changed.
Number display
Numbers are displayed only when value of common variables for #100 to #199 or local variables
is in a range bellow.
The display changes to [***********], if not in a range.
Meter:-999999.999 to 999999.999
(Integer: six figures, Decimal: three figures)
Inch:-99999.9999 to 99999.9999
(Integer: five figures, Decimal: four figures)
Not display all of the significant figures, when the number in a range.
Display number is rounded number.
Therefore, not always same the number on display and the correct conference of the variable.

Table of Contents