Chapter 7 Macro TC-32B
2004/01/22 7 - 24 eTCOMNCPR7-1.doc
7
M30; M99; 99; M99; M99;
7.5.5 Multiple nesting call
Macro calling depth of nesting is up to 4 -fold.
Local variables (#1 ~ #26)are provided for each macro level. When macro is called by G65, local
variable of called macro level is stored once, and new local variable of called macro program is
prepared. When M99 is executed, stored local variable becomes valid.
Common variables can be read and written even between different macro levels.
Level 0 Level 1 Level 2 Level 3 Level 4
Common variables : Commonly read and written from any macro level.
#100 ~ #199
#500 ~ #599
Main program
G65P8010
I3.J4.;
Program 8010
G65P8020
I5.J6.;
Program 8020
G65P8030
I7.J8.;
G65P8040
I9.J10.
;
Program 8030 Program 8040
#1
.
.
#4
#5
.
.
#9
#11
#13
#17
.
.
#26
#1
.
.
#4 3.0
#5 4.0
.
.
#9
#11
#13
#17
.
.
#26
#1
.
.
#4 5.0
#5 6.0
.
.
#9
#11
#13
#17
.
.
#26
#1
.
.
#4 7.0
#5 8.0
.
.
#9
#11
#13
#17
.
.
#26
#1
.
.
#4 9.0
#5 10.0
.
.
#9
#11
#13
#17
.
.
#26
Local variable o
f
level 0
Local variable of
level 1
Local variable o
f
level 2
Local variable o
f
level 3
Local variable of
level 4