TC-32B Chapter 7 Macro
2004/01/22 7 - 23 eTCOMNCPR7-1.doc
7
7.5.4 Difference between G65 and M98
1. Arguments can be designated for G65, but cannot be designated for M98.
2. Local variables are available for G65 depending on the depth of nesting, but are not
available for M98.
3. Calling depth of nesting for G65 is up to 4-fold.