TC-32B Chapter 7 Macro
2004/01/22 7 - 7 eTCOMNCPR7-1.doc
7
7.2.6 System variable
1. Interface input/output signal
Signal input #1000 ~#1015 R
Signal output #1100 ~ #1115 R/W
Signal batch reading (16 bits) #1032 R
Signal batch writing (16 bits) #1132 R/W
[Example of use]
A signal is output from the program to external output port 103.
- Assign #1100 to port N103 using the user parameter (external output signal).
- A signal is output to port 103 when the command is used in the program below.
:
#1100 = 1;
:
2. Workpiece coordinate origin
The workpiece coordinate origin is read and written.
Workpiece coordinate (External) #5201~ #5206 R/W
(G54) #5221~ #5226 R/W
(G55) #5241 ~#5246 R/W
··
··
(G59) #5321~#5326 R/W
(G54,1P1) #7001~#7006 R/W
(G54,1P2) #7021~#7026 R/W
··
··
(G54.1P48) #7941~#7946 R/W
3. Tool data
The tool length and tool dia. is read and written.
TL OFFSET #11001~#11099 R/W
FINE OFFSET #10001~#10099 R/W
TL ∅ COMP
#13001~#13099 R/W
FINE ∅ COMP
#12001~#12099 R/W