Chapter 7 Macro TC-32B
2004/01/22 7 - 8 eTCOMNCPR7-1.doc
7
4. Alarm indication
#3000 = n (ALARM MESSAGE)
Alarm number 9000 + n (n: 0 ~200) occurs, and the alarm message in the brackets (the first 20
characters, reset by the [RESET] key) is displayed.
Only alphanumerical characters are used in the brackets and registered in the alarm log.
[Example of use]
When the following block is executed:
#3000 = 6 (ABCD);
“9006 *ABCD” alarm occurs.
(Note) Command during tool radius compensation, feed to the position that
offset vector standing position be vertical to feed directin before.
5. Message display and stop
#3006 = (MESSAGE)
After execution of the previous block is stopped, a message up to 20 characters is displayed in
brackets. When the message contains 21 characters or more, only the first 20 characters are
displayed.
The alarm number is fixed at 9300 (stop level 1, reset level 1).
(Note) Command during tool radius compensation, feed to the position that
offset vector standing position be vertical to feed directin before.
6. Time
Time 1 #3001 R/W This timer counts the operation time in
increments of 10 msec.
The timer is reset to zero when the counted time
reaches 42949672.96 seconds (approx. 497 days)
or when power is turned on.
After resetting to zero, it starts counting.
Time 2 #3002 R/W This timer counts the time when the start LED is
lit (STL) in increments of 10 msec.
The timer is reset to zero when the counted time
reaches 42949672.96 seconds (approx. 497 days).
The value is stored even when the power is
turned off.
7. Operation control
Operation
control
#3003 R/W MFIN
0: WAIT
2: NOT WAIT
Operation
control
#3004 R/W FEED OVERRIDE EXACT STOP
0: VALID
2: INVALID
#3003
- “0” is set when power is turned on.
- “0” is set when the [RESET] button is pressed or M30 is used.
- When MFIN is set to [NOT WAIT], the program proceeds to the next block without
waiting for MFIN. In addition, MFIN is not confirmed to be OFF before the M signal is output.
- When MFIN is set to [NOT WAIT], the next M signal is output after the time set for [EXT
SIGNAL OUTPUT TIME (MFIN OFF)] (user parameter - switch 1) has elapsed.
#3004
- “0” is set when power is turned on.
- “0” is set when the [RESET] button is pressed or M30 is used.
- When [SPINDLE OVERRIDE] is set to [INVALID], override is fixed at 100%, regardless
of the position of the [OVERRIDE] switch on the operation panel.
- Spindle override and rapid feed override are also fixed at 100%.