Chapter 8 Automatic work measurement TC-32B
2004/01/30 8 - 22 eTCOMNCPR8-1.doc
8
When you continue to another measurement, previous measurement results are displayed.
T07005u2.bmp
8.4.2 Reflection of measured results on workpiece
coordinate system
The measured results are reflected in the workpiece coordinate system.
Command format G10 L99 Pn X_ Y_ Z_ Q_
Pn: n= 1 G54
2 G55
3 G56
4G57
5 G58
6 G59
Command format G10 L98 Pn X_ Y_ Z_ Q_
Pn: n=1 G54.1 P1
n=2 G54.1 P2
··
··
··
n=48 G54.1 P48
X, Y, Z .... Coordinate of the measured position
Q .... Measurement No. to be used
e.g. Assume that the value measured by measurement No. 2 is (X, Y) = (-80,
-120) in the machine coordinate system. To assign this position to (-40,